# CO2 NODE — COMMON  —  XIAO ESP32-C3 + Adafruit SCD30 (PID 4867)
# -----------------------------------------------------------------------------
# Rev 1.0-draft (2026-10-18). Shared byte for byte by bedroom-co2-node.yaml and
# family-room-co2-node.yaml, which hold only substitutions and their own API key
# (the mmwave-node-common.yaml pattern: one copy of the behaviour, not two).
#
# Hardware (Bill, 2026-10-18): a spare basement-node PCB ("Temp Humidity Sensor
# PCB"), SDA GPIO6 / SCL GPIO7, LED GPIO20. The SCD30 is the ONLY I2C device,
# cabled from its STEMMA QT socket to PH1, the 1x04 right-angle header:
#     pin 1 GND   pin 2 +3V3 (the SQUARE pad - not pin 1)   pin 3 SDA   pin 4 SCL
# = QT black / red / blue / yellow. VIN MUST be 3V3: the breakout's 10K SDA/SCL
# pull-ups (R3) go to VIN [S: the .brd netlist], so VIN sets the high level the
# XIAO's 3V3 pins see on the bus.
#
# THE UNATTENDED MOMENTS THIS FILE IS BUILT FOR
#   1. Every boot. ESPHome 2026.9.1 defaults automatic_self_calibration to TRUE
#      (scd30 sensor.py:65) and writes it to the sensor on every boot
#      (scd30.cpp:91). ASC assumes the sensor sees ~400 ppm air regularly; this
#      house has no HRV/ERV and a closed bedroom never does, so ASC would walk
#      the baseline upward unseen. It is set false here, explicitly.
#   2. Power-up. The first reading after power-up is 0 ppm (Adafruit SCD-30
#      guide p10, p16; ESPHome does not filter it). filter_out drops it - 0 ppm is
#      not a possible indoor value, so dropping every 0 costs nothing.
#   3. 03:00, the SCD30 stops answering (QT crimp, bus hang). HA must NOT keep
#      showing the last good number. After 4 missed 60 s reads the CO2 entity
#      goes unknown (NaN) and "CO2 Sensor Fault" turns on (1.3: so do the SCD30
#      temperature and humidity - the same read carries all three, and a failed
#      read publishes none, scd30.cpp:186-192). At 15 min the node
#      reboots to re-run SCD30 setup - at most 3 times in a row (the counter
#      survives the reboot), then it stays up and keeps reporting the fault, so
#      a dead cable cannot become a reboot loop that hides it.
#      1.4: reads come every 2 s, so 240 s is about 120 missed reads. The
#      watchdog blanks "CO2 (2 s)"; the 1-minute "CO2" follows at the end of
#      its minute, and so do T and RH, which are 1-minute means too.
#   4. The same 03:00, with no screen open (added 2026-10-27, Bill: "make the
#      led fault only with a test button"; the box is vented, so it shows).
#      The LED on GPIO20 strobes at 5 Hz while "CO2 Sensor Fault" is on, and
#      is dark otherwise. "LED Test" strobes it for 15 s, which proves the
#      pin, the LED and the light path without needing a fault.
#   5. A calibration months from now, by hand, with nobody to check it
#      (added 2026-10-27, firmware 1.2). Sensirion: FRC needs "a measurement
#      rate of 2s for at least two minutes before applying" it (SCD30
#      Interface Description v1.0-D1 p14); this node measures every 60 s.
#      frc_prepare opens a 20 min window at 2 s; forced_recalibration is
#      refused until 2 min into it; "Calibration" shows wait / ready / the
#      result in HA. The window ends with a reboot, whose setup writes the
#      60 s rate back: the SCD30 keeps its interval in non-volatile memory
#      (p9), so a forgotten window must not leave it at 2 s.
#      SUPERSEDED 2026-10-27 by 1.4 (moment 6): the node always measures at
#      2 s, so p14's condition holds from 2 min after every boot. frc_prepare,
#      its window and its reboot are gone; forced_recalibration is refused
#      only in the first 2 min after a boot.
#   6. Every reading, every night (added 2026-10-27, firmware 1.4, Bill:
#      "measure every 2 s all the time and send HA a 1-minute average and
#      show both on the graphs"). The SCD30 read 60 to 70 ppm lower at 60 s
#      than at 2 s in the same air [D: 3 rate switches on the porch, one
#      afternoon; H: CHANGELOG 2026-10-27], and FRC is taken at 2 s (p14).
#      So it now measures at 2 s always, the rate it was calibrated at. HA
#      gets "CO2", the 1-minute mean, and "CO2 (2 s)", every reading. Setup
#      writes the interval at every boot (scd30.cpp:68, 2026.10.0), so no
#      reboot can leave it at another rate.
#
# Calibration: with ASC off, the ONLY path is forced recalibration (the
# forced_recalibration API action below), done outdoors by hand.
# 1.2: call frc_prepare first, then forced_recalibration at "ready" (moment 5).
# 1.4: no frc_prepare; call forced_recalibration once Calibration reads
# "2 s rate; FRC ready".
# =============================================================================

substitutions:
  node_name: co2-node
  friendly: CO2 Node
  fw_version: "1.4-draft"   # 1.4 (2026-10-27): 2 s always; CO2 = 1-min mean, CO2 (2 s) = every read. 1.3 (2026-10-27): SCD30 temperature + humidity (diagnostic). 1.2 (2026-10-27): 2 s calibration window. 1.1: fault-only LED + LED Test

esphome:
  name: ${node_name}
  friendly_name: ${friendly}
  # Version floor: compiled on 2026.9.1 (the add-on's installed version on
  # 2026-10-18), re-compiled on 2026.10.0 (the add-on's version on 2026-10-27,
  # the first flash) and on nothing older. Raise it after a re-compile, never
  # as a side effect of an upgrade.
  min_version: 2026.10.0
  project:
    name: "wkcollis1.co2-node"
    version: ${fw_version}
  on_boot:
    priority: -100
    then:
      - output.turn_off: status_led_out        # the box is opaque; the LED stays dark
      # CHANGED 2026-10-27: the box is vented (Bill), and the LED is now the
      # fault light - see moment 4 and the second interval. This line only
      # sets the dark start; the interval drives it from the first tick.
      - lambda: |-
          // A clean boot starts clear; a recovery reboot carries its fault across
          // (globals are restored in setup, before this priority -100 trigger).
          id(co2_fault).publish_state(id(g_stale_reboots) > 0);
          id(g_last_co2_ms) = millis();        // the stale clock starts at boot
      # 1.4 (moment 5): setup has set 2 s, and p14 asks for 2 min at 2 s before FRC
      - delay: 2min
      - lambda: 'id(g_frc_ready) = true;'

esp32:
  board: seeed_xiao_esp32c3
  framework:
    type: esp-idf

# Logging over native USB Serial/JTAG (frees UART0/GPIO20 for the LED), as
# basement-th-node. First flash over USB, then OTA.
logger:
  level: INFO
  hardware_uart: USB_SERIAL_JTAG

debug:
  update_interval: 60s   # feeds the free-heap and loop-time diagnostics

wifi:
  ssid: !secret wifi_ssid
  password: !secret wifi_password
  power_save_mode: none
  reboot_timeout: 15min
  ap:
    ssid: "${friendly} Fallback"
    password: !secret ap_password

captive_portal:

api:
  reboot_timeout: 0s     # HA being down must not reboot the node (as basement-th-node)
  actions:
    # 1.4: frc_prepare (1.2, moment 5) is removed - the node is always at 2 s.
    # Forced recalibration. Run it OUTDOORS (or at an open window in steady air),
    # after the node has been powered and reading there for several minutes,
    # with the outdoor reference (~420 ppm). Never from an automation: a
    # reference given indoors bakes the room's excess into every later reading.
    - action: forced_recalibration
      variables:
        reference_ppm: int
      then:
        # CHANGED 2026-10-27 (1.2): the window guard runs FIRST, so a test call
        # with 399 ppm is refused by both guards and can never apply.
        # 1.4: the time guard is now 2 min since boot (g_frc_ready, on_boot).
        - if:
            condition:
              lambda: 'return id(g_frc_ready);'
            then:
              - if:
                  condition:
                    lambda: 'return reference_ppm >= 400 && reference_ppm <= 2000;'
                  then:
                    # 1.2: a direct call, because the scd30 action discards the
                    # result, and "applied" must mean the SCD30 took it.
                    - if:
                        condition:
                          lambda: 'return id(scd30_sensor).force_recalibration_with_reference((uint16_t) reference_ppm);'
                        then:
                          - lambda: 'id(g_frc_last) = "applied " + std::to_string((int) reference_ppm) + " ppm";'
                          - logger.log:
                              level: WARN
                              format: "FRC applied: reference %d ppm"
                              args: ['(int) reference_ppm']   # API int is int32_t = long on the C3
                        else:
                          - lambda: 'id(g_frc_last) = "FAILED: the SCD30 did not take it";'
                          - logger.log:
                              level: ERROR
                              format: "FRC failed: the SCD30 did not take %d ppm"
                              args: ['(int) reference_ppm']   # API int is int32_t = long on the C3
                  else:
                    - lambda: 'id(g_frc_last) = "refused: " + std::to_string((int) reference_ppm) + " is outside 400-2000";'
                    - logger.log:
                        level: ERROR
                        format: "FRC refused: %d ppm is outside 400-2000"
                        args: ['(int) reference_ppm']   # API int is int32_t = long on the C3
            else:
              - lambda: 'id(g_frc_last) = "refused: under 2 min since boot";'
              - logger.log:
                  level: ERROR
                  format: "FRC refused: wait 2 min after boot at the 2 s rate"

ota:
  - platform: esphome
    password: !secret ota_password

i2c:
  sda: GPIO6          # D4
  scl: GPIO7          # D5
  frequency: 50kHz    # Adafruit SCD-30 guide p15-16
  scan: true
  # As basement-th-node. [I] scd30.cpp's own comment says the SCD30 can stretch
  # SCL up to 150 ms; if bring-up logs show I2C read errors, raise this first.
  # CORRECTED 2026-10-27 (R13; the error was in the 10-18 draft): raising it
  # cannot work. The ESP-IDF bus clamps any timeout above 13 ms to 13 ms and
  # logs "Using max allowed timeout: 13 ms" at every boot (i2c_bus_esp_idf.cpp
  # 26-29, the same in 2026.9.1 and 2026.10.0; seen on the first boot,
  # 2026-10-27). So 50ms here runs as 13 ms. The SCD30's own defence against a
  # long stretch is the 30 ms delays between its setup writes (scd30.cpp).
  timeout: 50ms

globals:
  - id: g_last_co2_ms
    type: uint32_t
    restore_value: false
    initial_value: '0'
  - id: g_stale_reboots
    type: int
    restore_value: true     # must survive the reboot it counts
    initial_value: '0'
  - id: g_led_test
    type: bool
    restore_value: false    # a reboot ends a test
    initial_value: 'false'
  - id: g_frc_ready        # 1.4: true from 2 min after boot (on_boot); replaces g_frc_open_ms
    type: bool
    restore_value: false    # every boot waits its own 2 min at 2 s
    initial_value: 'false'
  - id: g_frc_last         # moment 5: the last calibration result, shown in HA
    type: std::string
    restore_value: false
    initial_value: '""'

script:
  - id: led_test
    mode: restart           # a second press restarts the 15 s
    then:
      - logger.log:
          level: INFO       # visible at this build's INFO level: proves the press arrived
          format: "LED test: 15 s strobe"
      - lambda: 'id(g_led_test) = true;'
      - delay: 15s
      - lambda: 'id(g_led_test) = false;'
  # 1.4: frc_window (1.2) is removed with frc_prepare - setup sets 2 s itself.

output:
  - platform: gpio
    pin: GPIO20         # D7 (UART0 RX; freed because logging is over USB)
    id: status_led_out

button:
  - platform: restart
    name: "Node Restart"
    entity_category: config
  - platform: template
    name: "LED Test"        # moment 4 above
    icon: mdi:led-on
    entity_category: config
    on_press:
      - script.execute: led_test

sensor:
  - platform: scd30
    id: scd30_sensor
    address: 0x61
    automatic_self_calibration: false   # moment 1 above
    altitude_compensation: 157m         # ~515 ft (Bill) x 0.3048 = 156.97 m
    # CHANGED 2026-10-27 (1.4, moment 6): 60s -> 2s. This is the SCD30's own
    # measurement interval, written at every boot (scd30.cpp:68), and each
    # reading is published as it comes (scd30.cpp:187-192).
    update_interval: 2s
    # No temperature: or humidity: here, deliberately. The SCD30's T/RH are
    # self-heated, and the room already has its own T/RH sources (R10).
    # CHANGED 2026-10-27 (1.3, Bill: "can we see the units temp/humidity its
    # recording?"). Added as DIAGNOSTIC entities, not as room readings: they are
    # the SCD30's own on-board sensor (Sensirion SCD30 Design-In Guidelines D1 p1),
    # self-heated (Interface Description v1.0-D1 p15), so they read warm and dry.
    # Their use is calibration: FRC assumes the sensor is in thermal equilibrium
    # with its surroundings (Design-In p2), and this temperature shows when it is.
    # No temperature_offset: setup writes the offset to the SCD30 at every boot
    # either way (scd30.cpp:42-49: 0 when the key is absent, as in 1.2), so 1.3
    # sends the sensor nothing that 1.2 did not.
    # CHANGED 2026-10-27 (1.4): this is now "CO2 (2 s)", every reading; "CO2",
    # the 1-minute mean HA has always had, is the copy sensor below.
    co2:
      id: co2_2s
      name: "CO2 (2 s)"
      accuracy_decimals: 0
      filters:
        - filter_out: 0.0                # moment 2 above
      on_value:
        then:
          - lambda: |-
              if (std::isnan(x)) return;   // the watchdog's own NaN must not reset the watchdog
              id(g_last_co2_ms) = millis();
              if (id(g_stale_reboots) != 0) id(g_stale_reboots) = 0;
              if (id(co2_fault).state) id(co2_fault).publish_state(false);
    temperature:
      id: scd30_temperature
      name: "SCD30 Temperature (self-heated)"
      accuracy_decimals: 1
      entity_category: diagnostic
      filters:
        - throttle_average: 60s          # 1.4: a 1-minute mean, as at 60 s
    humidity:
      id: scd30_humidity
      name: "SCD30 Humidity (self-heated)"
      accuracy_decimals: 1
      entity_category: diagnostic
      filters:
        - throttle_average: 60s          # 1.4: a 1-minute mean, as at 60 s

  # 1.4 (moment 6): "CO2", the 1-minute mean of "CO2 (2 s)". The same name
  # keeps the object id, so HA keeps the entity and its history. copy forwards
  # the source's filtered state, NaN included (copy_sensor.cpp:9), and inherits
  # its unit, device class and decimals. throttle_average (filter.cpp:171-194)
  # sends the mean of the minute's numbers; a minute with none but the
  # watchdog's NaN sends NaN, and a minute with nothing sends nothing.
  - platform: copy
    source_id: co2_2s
    id: co2
    name: "CO2"
    filters:
      - throttle_average: 60s

  - platform: template
    name: "CO2 Stale Reboots"
    entity_category: diagnostic
    accuracy_decimals: 0
    update_interval: 60s
    lambda: 'return id(g_stale_reboots);'

  - platform: wifi_signal
    name: "Node WiFi Signal"
    update_interval: 60s
    entity_category: diagnostic
  - platform: uptime
    name: "Node Uptime"
    update_interval: 60s
    entity_category: diagnostic
  - platform: debug
    free:
      name: "Node Free Heap"
      entity_category: diagnostic
    loop_time:
      name: "Node Loop Time"
      entity_category: diagnostic

text_sensor:
  - platform: template
    id: calibration_text
    name: "Calibration"      # moment 5 above
    icon: mdi:tune-vertical
    entity_category: diagnostic
    update_interval: 5s
    # CHANGED 2026-10-27 (1.4): no window to report; and it publishes only on
    # a change (an empty optional publishes nothing, template_text_sensor.cpp:9-14).
    lambda: |-
      std::string s = id(g_frc_ready) ? "2 s rate; FRC ready" : "2 s rate; FRC wait (2 min after boot)";
      if (!id(g_frc_last).empty()) s += "; " + id(g_frc_last);
      if (id(calibration_text).state == s) return {};
      return {s};
  - platform: version
    name: "Node ESPHome Version"
    entity_category: diagnostic
  - platform: debug
    reset_reason:
      name: "Node Reset Reason"
      entity_category: diagnostic

binary_sensor:
  - platform: status
    name: "Node Status"
  - platform: template
    id: co2_fault
    name: "CO2 Sensor Fault"
    device_class: problem
    entity_category: diagnostic

interval:
  # Moment 3 above. 240 s: 4 missed 60 s reads raise the fault for certain (3 can,
  # if a tick lands just ahead of the 4th read). The SCD30 measures on its own
  # 60 s clock (scd30.cpp:68), so after boot the dropped 0 ppm read comes at
  # ~60 s and the first real one at ~120 s. [I] that leaves ~120 s of margin;
  # falsified if a boot with a working sensor logs "no SCD30 reading" (a brief
  # fault, no reboot - the reboot needs 900 s).
  # OBSERVED 2026-10-27 (bedroom node, one cold USB power-up, n=1): the first
  # CO2 value reached the API at +60.7 s after power-on, not ~120 s, and no
  # 0 ppm value was published; later reads came at 61 s steps. So the margin
  # is ~180 s [D: 240 - 60.7], not ~120 s; no "no SCD30 reading" in 330 s.
  # Whether this SCD30 emitted a 0 that filter_out dropped is not seen: the
  # raw read logs at DEBUG and this firmware logs at INFO.
  # 1.4: at 2 s the first reading should come within seconds of boot [I:
  # falsified as above], and 240 s is about 120 missed reads. The NaN goes to
  # "CO2 (2 s)"; the copy carries it to "CO2" at the end of its minute.
  - interval: 30s
    then:
      - lambda: |-
          const uint32_t age = millis() - id(g_last_co2_ms);   // unsigned: survives the 49-day wrap
          if (age < 240000) return;
          if (!id(co2_fault).state) {
            id(co2_fault).publish_state(true);
            ESP_LOGW("co2", "no SCD30 reading for %u s", (unsigned) (age / 1000));
          }
          if (!std::isnan(id(co2_2s).state)) id(co2_2s).publish_state(NAN);   // 1.4: the raw; the mean follows
          // 1.3: T and RH come from the same read, so they are just as stale
          if (!std::isnan(id(scd30_temperature).state)) id(scd30_temperature).publish_state(NAN);
          if (!std::isnan(id(scd30_humidity).state)) id(scd30_humidity).publish_state(NAN);
          if (age >= 900000 && id(g_stale_reboots) < 3) {
            id(g_stale_reboots) += 1;
            ESP_LOGE("co2", "stale %u s: recovery reboot %d of 3", (unsigned) (age / 1000), id(g_stale_reboots));
            // safe_reboot() alone persists the count [2026.9.1 source]: shutdown hooks run
            // lowest priority first, so the global (HARDWARE) stores itself before the
            // preferences syncer (BUS) flushes NVS. (The first draft, 2026-10-18, called
            // global_preferences->sync() here first - a no-op for this count, because the
            // global had not stored the new value yet. Removed, recorded per R13.)
            App.safe_reboot();
          }

  # Moment 4 above (added 2026-10-27). 5 Hz: 100 ms on, 100 ms off, while the
  # fault is on or a test runs; dark otherwise. It reads co2_fault itself - the
  # entity HA shows - so the LED and HA cannot disagree (R10), and the fault a
  # recovery reboot carries across (on_boot) keeps it strobing after that boot.
  # It toggles per tick instead of using millis() % period, so a late tick
  # cannot merge two on-phases. It must stay SECOND: harness/gen.py reads
  # interval[0] as the watchdog; harness/led.py tests this one.
  - interval: 100ms
    then:
      - lambda: |-
          static bool lit = false;
          lit = (id(co2_fault).state || id(g_led_test)) && !lit;
          if (lit) id(status_led_out).turn_on();
          else id(status_led_out).turn_off();